Environmental equipment | home of craftsmen
Professional supplier and service provider of thermal equipment
The use of water without water treatment of water minerals, especially more, although some of the water we look very clear, no turbidity phenomenon, but after the boiler liner water repeatedly burned and boiled after the minerals inside the water without water treatment will produce chemical reflections more serious, they will be adhered to the heat pipe and the level controller.
1, too much dirt level controller, in the use of the process will fail, will not work, the heating pipe will burn out.
2, too much dirt on the exterior of the heating pipe, the heating time will be extended, will increase power consumption.
When using the steam generator should pay attention to timely sewage, sewage twice a day, sewage should be discharged with a pressure of 0.15 MPA discharge, only then will prevent clogging of the pipeline, sewage pipes properly connected to avoid scalding, the correct operation of the steam generator will make the life of the machine will be greatly increased, and will also save electricity costs. After the boiler scaling, if we still want to achieve the temperature of the furnace water without scale, it is inevitable to increase the temperature of the heating surface. For example: 10 tons of boilers, wall temperature of 280 ℃, when the knot silicate scale 1 mm, to achieve the same temperature of the furnace water, the wall temperature to be raised to 680 ℃, and at this time the furnace steel plate strength is reduced, serious cases will cause an explosion, and the temperature increases lead to the destruction of the application of the material ability to destroy; energy consumption increases. To the boiler system for the purpose of water treatment is very clear, we want to eliminate scale to the boiler to bring harm, saving energy consumption and extend the service life of the boiler and get a high rate of operational integrity. According to the national requirements for steam boiler water supply, must be used outside the furnace to remove calcium and magnesium ions, that is, must be used to soften the water as the boiler's water supply. In the steam generator, the ionic resin method is used to soften the water as the feed water for the heater, so that the impact of scale on the heater can be effectively reduced.
Contact Us
National service hotline:13829262146
Address:No. 6, Road 1, Shegang Industrial Zone, Humen Town, Dongguan, China
TEL:0769-85245101
fax:0769-85247528
Email:13829262146@139.com
technical support:MYIT
Scan QR code to share to WeChat
0769-85245101